HYDRAULIC BOILER TUBE CLEANING
The twin auger system conveys ash from the combustion chamber. Combustion grate ash is conveyed via a twin auger system to the external ash bin. The cyclone ash is automatically conveyed to a separate ash bin placed under the multi-cyclone and ash dust is metered into the bin via an airlock rotary valve. Both ash bins are fitted with ultrasonic level sensors which illustrate the ash level on the main controller and when the bin is full an SMS text and Email will be sent to relevant personnel to notify them that the ash bin requires emptying.
PNEUMATIC TUBE CLEANING
The option for a compressed air pneumatic cleaning system is also available. Compressed air is stored in a compressed air tank. This system generates a large volume of air under high pressure that is blown through a special pneumatic valve in a fraction of a second and removes sediments in the boiler tubes. Automatic valve control cleaning intervals can be set according to the quality of fuel being consumed.